Water Damaged Bus Plugs – How Do You Know

March 23rd, 2011 Comments off

MIDWEST was asked how we can tell if a bus plug has been water damaged. What if a brand new bus plug is exposed to water, say rain. How can we tell after it has already dried off? If it’s new, how would MIDWEST even know it was exposed to rain or water? The answer goes to the heart of why MIDWEST fully reconditions bus plugs. If a bus plug has been exposed to water, we would know as soon as we disassemble it for reconditioning. The old or new bus plug hardware, nuts and bolts and washers, would have some rust. The exposed surfaces of bolt holes would have rust at the edges. This is more obvious than you might think. In addition, between the inside of the new bus plug enclosure and attached interior parts, we find dust that has the visual pattern of water exposure. Like spilling water on a surface that had just a little dust on it. After the water evaporates, you can still see the pattern of the water exposure on the surface. Usually all this is pretty obvious to the engineering technician doing the work, if they are actually reconditioning the replacement bus plugs. But, if a company is just giving it a shoe shine, meaning a little inside cleaning with a little outside painting, they may never detect the water damage. Even an insulation resistance test pole to pole and pole to ground may not reveal the damage. But it is there and it shortens the reliable life expectancy of the bus plug. Rust especially is insidious when it starts at support hardware. MIDWEST’s best suggestion is to buy fully reconditioned equipment if you are buying obsolete bus plugs, used bus plugs, or new surplus bus plugs. This is true whether buying Square D bus plugs, Siemens bus plugs, ITE bus plugs or any other manufacturer’s product.    

Replace Bus Plugs Due to Failure, Not Just New Load

January 26th, 2011 Comments off

 

Cutler Hammer CP2HD366 Bus Plugs For Sale by MIDWEST

Cutler Hammer CP2HD366 Bus Plugs For Sale by MIDWEST

Much of the demand for reconditioned and new surplus bus plugs is because the user has to replace bus plugs that are defective.  One of the worst things that happen is the bus plug operating mechanism breaks when you try to open or close it. It is very dangerous if the bus plug is half open or one pole opened and the other two are half closed yet. This type of failure is due to the lack of maintenance, specifically the lack of exercising the bus plug operating mechanism periodically. The other enemies are dirt, moisture, heat, and, as we have said many times, fork lifts.  Sometimes folks are very surprised that so many reconditioned bus plugs are used to replace damaged or defective bus plugs rather than just for additional load or expansion.

 

Federal Pacific LSP1432 Bus Plugs For Sale by MIDWEST

Federal Pacific LSP1432 Bus Plugs For Sale by MIDWEST

For every Cutler Hammer CP2HD366 bus plug purchased for an expansion project, we might also replace a Federal Pacific LSP1432SN bus plug because the customer’s existing bus plug failed to operate properly. When it comes to bus plugs, run to failure is the standard operating mode. The perception is they don’t need maintenance because the never do anything. They just sit on the bus duct. And that is true, but it is also the reason they eventually may fail to operate properly when needed.

The only real pattern may be the use of newer style replacement bus plugs for expansion projects than for replacement of defective equipment